Temperature |
 |
SmartReader
Multi-channel, configurable data loggers
|
|
SmartReader
SmartReader 1 is an easy to use data logger for effortless
temperature recording. Quick and easy to set up, it works
right out of the box, logging temperature readings from
its internal, precision-calibrated, on-board sensor. For
added versatility, you can also use an optional remote temperature
probe.
| Multi-channel,
configurable data loggers |
| SmartReader
|
| For
further specifications on individual models |
| Size
|
107
mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9") |
 |
| Weight:
|
110
grams (3.75 ounces) |
 |
| Case
Material: |
NorylŪ
Plastic |
 |
| Operating
Limits: |
-40°C
to 70°C (-40°F to 158°F) and 0 to 95% Relative
Humidity (non-condensing) |
 |
| Clock
Accuracy: |
+/-2
seconds per day |
 |
| Battery:
|
3.6
volt Lithium, 1 Amp-Hour |
 |
| Power
Consumption: |
5
to 10 microamps (continuous) |
 |
| Battery
Life: |
10-years
warrantied (under normal use) Factory replaceable
|
 |
| Mounting:
|
Magnetic
backing or locking eyelet |
 |
| Memory
Size: |
32
K (32,768 readings) |
 |
| Sampling
Method: |
1.
Continuous (First-in, First-out) 2. Stop when
full (Fill-then-stop) |
 |
| Sampling
Rate: |
User
selectable rates between 8 seconds to once every
5 days |
 |
| Resolution:
|
8
bits (1 part in 256) |
 |
| External
Connector: |
Removable
screw-type terminal strip with Common (-) connection
|
 |
| PC
Requirements: |
IBM
PC or 100% compatible running MSŪ Windows 3.1,
'95, '98, or NT, with at least 2 MB RAM, 2 MB
of hard drive disk space and one free serial port
|
 |
| Product
Approvals: |
Meets
Part 15 for Digital Devices of the Code of Federal
Regulations of the Federal Communications Commision
(FCC). Meets Class A radiated and conducted emission
requirements of Section 2 of the Radio Interference
Regulations of Communications Canada. IEC801-2,
3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst
and Radiated Emissions respectively, for the Commission
of the European Communities (CE) |
 |
| Resistance
to X-Rays: |
Tested
for protection against a 160kV dose @ 5mA for
30 seconds (150mA-sec) @ 38 inches F.F.D. (about
100 times that of an airport X-Ray machine). Tested
for protection against Gamma Ray (equivalent to
0.137 - 1.38 mega volts) IR 192 - 28 curies @
30 second exposure source to object distance 5"
|
 |
|
|
|
M&L Testing Equipment
(1995) Inc.Canada, carries a large inventory of materials testing equipment.
If you have
any questions regarding a listed product, or if you do not see the equipment
you require, please contact us by using our Contact
Form or E-mail us @
.
A representative will contact you regarding your request shortly.
M&L Testing Equipment
(1995) Inc. ©1996-2007 - 31 Dundas St. (Hwy # 5) Dundas, Ontario,
Canada L9H 7H8
Tel: (905)
689-7327 Fax: (905) 689-3978 Toll Free: 1-800-263-9244
click for map & directions
Calgary Office: 4530-14th St. N.E., Calgary, Alberta Canada
T2E 6T7
Tel: (403) 250-6765 Fax: (403) 250-6803Toll Free: 1-800-663-4779