Thermolyne
Products |
 |
|
|
Thermolyne
NCAT Asphalt Content Tester
|
Thermolyne
NCAT Asphalt Content Tester
NCAT, the National Center for
Asphalt Technology has developed an environmentally friendly
and cost effective method for determining asphalt content.
A 12 lab round robin field test has been conducted by NCAT
exclusively with the Thermolyne NCAT Asphalt tester. Results
and proven performance are documented by NCAT.
Thermolyne's
NCAT tester provides asphalt content of bituminous paving
mixtures accurate to 0.11%. This method provides a clean
aggregate sample for gradation analysis.
- Saves
You Time
- Easy
To Operate
- Saves
You Money
- Safe
To Use
- Software
Convenience
|
Back
to top
|
Moisture
Determination
Ovens

|
A fully
automatic moisture determination oven for asphalt mix, aggregates,
and soils.
A
sample is dried to .01% of initial sample weight. This durable
unit complies with ASTM 2216-92 and numerous stae D.O.T.
oven drying methods.
- 150°C
(302°F) maximum temperature
-
P.I.D. microprocessor controls temperature to ± 1.0°C
-
1.1 cu. Ft. (31.1 l) or 1.7 cu. ft. (48.1 l) chamber capacity
-
24 Month Warranty PERFECT FOR INERT ATMOSPHERE MOISTURE
TESTING
|
| Model |
Chamber
Dimensions Inches( cm) |
Overall
Dimensions Inches( cm) |
Volts
(phas)t |
Temp
Range |
|
W |
H |
D |
W |
H |
D |
|
(Stability) |
(Uniformity) |
| OV114525 |
12(30.8) |
19.5(49.5) |
17.5(44.5) |
21.5(54.6)
|
35.5(90.2)
|
25(63.5)
|
120
|
@100°C=±0.3°C
|
@100°C=±1°C
|
| OV114520 |
12(30.8) |
19.5(49.5) |
17.5(44.5) |
21.5(54.6)
|
35.5(90.2)
|
25(63.5)
|
240
|
@200°C=±0.6°C
|
@200°C=±4.2°C
|
| AY1145X3 |
Accessory
pans and handle fork |
|
|
|
|
|
Back
to top
|
Heavy
Duty
Ovens

|
LC-8
and LC-12, heavy duty ovens designed for today's materials
testing laboratory. You'll find the horizontal airflow provides
excellent temperature stability and uniformity performance
in these 8 and 12 cu. ft. models.
Designed
with SUPERPAVE in mind...
These large capacity ovens are able
to take on the big heavy loads. The heavy duty shelves will
hold up to 200 pounds each. These shelves are perfect for
gyratory compactor molds.
The
heating elements and fans have been designed into the top
of the ovens.
Superior Features...
-
Digital PID controller allows for precise temperature
control.
- Hydraulic
controlled over-temperature protection ensures oven temp.
will not exceed preset limits
- 240
volt, 15 amp electrical service allows for fast heat-up
and recovery times
- The
LC-8 and LC-12 provide temperature uniformity of +/- 3
deg. C at 150 °C
- Both
units have a temperature range of + 10 degrees above above
ambient to 250 degrees Celsius
|
| Model |
Chamber
Volume |
Chamber
Dimensions
Inches( cm) |
Overall
Dimensions Inches( cm) |
Volts |
Amps |
Watts |
Stability |
Uniformity |
|
|
W |
H |
D |
W |
H |
D |
|
|
|
|
|
| OV116040 |
8
cu.ft |
26(66) |
21(53.3) |
26(66) |
34.5(87.6) |
35(88.9) |
31(78.7) |
220-240 |
12.5 |
3000 |
±0.2@150°C |
±3°@150°C |
| OV116850 |
12.5
cu.ft |
26(66) |
32.5(82.5) |
26(66) |
35(88.9) |
53.75(136.5) |
34(86) |
220-240 |
20.5 |
4000 |
±0.2@150°C |
±3°@150°C |
|
Back
to top
|
Vacuum
Ovens

|
For
use in the degassing process of the binder that has been
removed from the Pressure Aging Vessel in accordance with
AASHTO PP1-98.
Immediately
following the degassing process, the material can then be
tested in the Bending Beam Rheometer or the Dynamic Shear
Rheometer or the Direct Tension device.
Degassing of the material prior to these tests insures that
the material does not contain air bubbles.
Entrapped air can compromise the integrity of the binder
material, thus causing false failures in the previously
mentioned test devices.
All
The Features You Have Come To Expect From Thermolyne
- Powder
coated heavy gauge steel exterior for longevity
- Easy
to clean stainless steel chamber interior for ease of
use
- Exclusive
polycarbonate safety shield protects door glass
- Silicone
door gasket and positive latch door maintain seal at all
vacuum levels for accurate results
- Two
removable aluminum shelves included standard with each
unit.
- Radiant
warm wall heating provides uniformity and preserves working
chamber space.
- 3"
glass wool insulation prevents heat loss from working
chamber.
|
- Digital
P.I.D. temperature controller provides excellent temperature
control for consistent results.
-
Top mounted independent evacuation and venting vacuum
fittings are unique from all other models which feature
front mounted three-way valve for evacuation, venting
and purging of inert gasses with vacuum fittings.
-
Vacuum Fittings Require 1/2" I.D> Tubing
-
Vacuum levels are displayed on gauges in inches
of mercury.
-
All controls conveniently located on side mounted panel
for easy operation
-
Maximum temperatures 220 deg. C.
-
Two Year Warranty
| Model |
Chamber
Dimensions |
Overall
Dimensions
Inches( cm) |
Weight |
Volts |
Amps |
Watts |
Temp.
Display |
|
W |
H |
W |
H |
D |
|
|
|
|
|
| 3606PAV |
8(20) |
8(20) |
17(43) |
17.375
(44) |
16(41) |
57(26) |
120 |
5.0 |
600 |
digital |
| 3606-1PAV |
8(20) |
8(20) |
17(43) |
7.375
(44) |
16(41) |
57(26) |
240 |
2.5 |
600 |
digital |
|
|
M&L Testing Equipment
(1995) Inc.Canada, carries a large inventory of materials testing equipment.
If you have
any questions regarding a listed product, or if you do not see the equipment
you require, please contact us by using our Contact
Form or E-mail us @
.
A representative will contact you regarding your request shortly.
M&L Testing Equipment
(1995) Inc. ©1996-2007 - 31 Dundas St. (Hwy # 5) Dundas, Ontario,
Canada L9H 7H8
Tel: (905)
689-7327 Fax: (905) 689-3978 Toll Free: 1-800-263-9244
click for map & directions
Calgary Office: 4530-14th St. N.E., Calgary, Alberta Canada
T2E 6T7
Tel: (403) 250-6765 Fax: (403) 250-6803Toll Free: 1-800-663-4779
e-mail:
Site
Updated December 12, 2008
web design
by: Virtual
Image,
Dundas
|
|