Fast, Easy-to-Use and Accurate!
The Tel-Tru Check-Temp Calibrator is a dry block temperature calibrator that allows accurate verification of thermometer accuracy at the temperature point critical to the users actual application.
As part of your HACCP Program, use Tel-Tru Check-Temp Calibrators to verify the accuracy of your food service and laboratory thermometers. Environmental Safety and Health Professionals, Quality Assurance Managers and HACCP Coordinators in food processing and smoking, preparing and cooking, holding and serving and cooling and storage are using the Check-Temp Calibrator to verify the accuracy of their dial and digital thermometers.
|
|
Check-Temp II M and Check-Temp 40 M
These multi-hole Check-Temp Calibrators allow you to verify the accuracy of dial thermometers and digital probes of all sizes. The multi hole units fit probes up to .250", .125", .187" and .375" diameter.
|
Note: Image above is an enlarged view of 4 holes
|
RELIABLE ACCURACY:
- Accuracy ±0.2°F.
- Each unit serialized and certified traceable to NIST.
- Built in circuitry to warn if unit is more than 1°F out of calibration.
- Optional factory re-certification and maintenance program.
- Simple Set Up - Plug in and turn it on!
Use With Dial TypeThermometers - Built in tool for holding the calibration nut makes adjustments FAST and EASY.
Use With Digital Thermometers - Compare actual performance to accuracy specifications.
Temperature Units - Check & calibrate at your critical temperature point.
- Check-Temp 140°F - High temperature unit, fits probes up to .150" diameter.
- Check-Temp 160°F - Temperature at which E. Coli and other pathogens are killed. High temperature unit, fits probes up to .150" diameter.
- Check-Temp 40°F M - Low temperature unit with four holes, fits probes up to .250", .125", .187" and .375" diameter.
- Check-Temp II M - Dual cold and hot (40°F and 160°F) unit with four holes, fits probes up to .250",.125", .187" and .375" diameter.
Custom hole diameters available--Consult M<esting. Custom temperature points available--Consult M<esting.
|
SPECIFICATIONS |
CHECK-TEMP 40 M
|
CHECK-TEMP 140
|
CHECK-TEMP 160
|
CHECK-TEMP II M
|
Setpoint |
40°F |
140°F |
160°F |
40°F and 160°F |
Accuracy |
±0.2°F |
±0.2°F |
±0.2°F |
±0.2°F |
Stability |
±0.09°F |
±0.06°F |
±0.06°F |
±0.07°F |
Heating Time |
Approx. 3 min. |
Approx. 8 min. |
Approx. 10 min. |
Approx. 3 min. |
Fits Probes Up To |
.250", .125", .187"and .375" |
.150" |
.150" |
.250", .125", .187" and .375" |
Voltage |
90 to 130 VAC, 50/60 Hz |
90 to 130 VAC, 50/60 Hz |
90 to 130 VAC, 50/60 Hz |
90 to 130 VAC, 50/60 Hz |
Power |
25 Watts |
45 Watts |
45 Watts |
25 Watts |
Weight |
9.2 lbs. |
8.9 lbs. |
8.9 lbs. |
9.2 lbs. |
Housing Material |
Stainless Steel 304SS |
Stainless Steel 304SS |
Stainless Steel 304SS |
Stainless Steel 304SS |
Size |
3-1/16" H x 6-5/8" W x 10-7/8"D (78 mm x 168 x 276 mm) |
3-1/16" H x 6-5/8" W x 10-7/8"D (78 mm x 168 x 276 mm) |
3-1/16" H x 6-5/8" W x 10-7/8"D (78 mm x 168 x 276 mm) |
3-1/16" H x 6-5/8" W x 10-7/8"D (78 mm x 168 x 276 mm) |
|
*HIGH TO LOW or LOW TO HIGH takes approximately 5 minutes
OPTIONS AND ACCESSORIES:
- Annual Re-certification & Maintenance Notification Service
- Custom hole diameters and temperature points available--Consult Factory
- Carrying Case - Padded CORDURA® nylon
- Dial Adjustment Tool - For 1" and 2" Thermometers
- Cleaning Brushes
- NEW--Tip Sensitive Probe Adapter
|
TIP SENSITIVE PROBE ADAPTER
Tip Sensitive Probe Adapter:
The probe adapter sleeve is to be used when calibrating electronic probes. Fits into the 3/8" diameter hole of Check-Temp 40 M and Check-Temp II M. When adapter is used Check-Temp accuracy is ±1%. Use with probes 3-3/8" minimum length or greater and 3/16" maximum OD or smaller.P
Note: Calibrator accuracy, with sleeve, is +/- 1%.
|
|